80070221-0b0affff : Sensor [SensorElementName] has transitioned to critical from a less severe state.
Sensor [SensorElementName] has transitioned to critical from a less severe state.
IMM has detected an Over Temperature Condition for the ML2 adapter.
May also be shown as 800702210b0affff or 0x800702210b0affff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
Complete the following steps until problem is solved:
- Check the IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Check IBM Support site for Service Bulletins/RETAIN tips related to an ML2 Fault Condition.