80070107-2583ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state.
Sensor [SensorElementName] has transitioned from normal to non-critical state.
How the CPU's are installed in the system does not match a supported configuration and may make CPU's inaccessible to the operating system and prevent boot. [CPU Population]
May also be shown as 800701072583ffff or 0x800701072583ffff
Severity
Warning
Alert Category
Warning - Other
Serviceable
Yes
SNMP Trap ID
60
Automatically Notify Support
No
User Response
Complete the following steps:
- Check the IBM ServerProven Web site to validate that the processor is a valid option for this system. If not, remove the processor and install one that is a valid option.
- Verify that matching processors are installed in the correct population sequence for the system. See the system documentation.
- Check the IBM support site for service bulletins or firmware updates that apply to this processor error.
- Replace the processor. While replacing the processor, inspect the processor socket and replace the CPU / Memory board if the processor socket is damaged.