Skip to main content

806f090c-2b82ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.

[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.

Memory on Compute Book 2 has been throttled due to high temperature detected by the DIMM sensor.

May also be shown as 806f090c2b82ffff or 0x806f090c2b82ffff

Severity

Warning

Alert Category

System - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0142

SNMP Trap ID

22

Automatically Notify Support

No

User Response

Complete the following steps until problem is solved:

  1. Check the IMM event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.
  5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.