806f010d-2b81000a : The [NumericSensorElementName] has been disabled due to a detected fault.
The [NumericSensorElementName] has been disabled due to a detected fault.
The eXFlash Proxy Service detected a fault on the eXFlash DIMM 10 in Compute Book 1.
May also be shown as 806f010d2b81000a or 0x806f010d2b81000a
Severity
Error
Alert Category
Critical - Hard Disk drive
Serviceable
Yes
SNMP Trap ID
5
Automatically Notify Support
Yes
User Response
- Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
- Reinstall your eXFlash IPMI Proxy Service.
- Perform a full AC power cycle on the system.
- If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)
- Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.
- If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlash DIMM is under warranty before replacement.
- Replace compute book.
- (Trained Service technician only) Replace affected Processor.
Give documentation feedback