806f090c-2b83ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Memory on Compute Book 3 has been throttled due to high temperature detected by the DIMM sensor.
May also be shown as 806f090c2b83ffff or 0x806f090c2b83ffff
Severity
Warning
Alert Category
System - Other
Serviceable
Yes
SNMP Trap ID
22
Automatically Notify Support
No
User Response
Complete the following steps until problem is solved:
- Check the IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.
- If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
Give documentation feedback