80070603-1301ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Voltage Regulator Error.
May also be shown as 800706031301ffff or 0x800706031301ffff
Severity
Error
Alert Category
Critical - Power
Serviceable
yes
SNMP Trap ID
4
Automatically Notify Support
no
User Response
- Compute Book 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or microprocessor 1 itself
- Compute Book 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or microprocessor 2 itself
- Compute Book 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or microprocessor 3 itself
- Compute Book 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or microprocessor 4 itself
- Planar VRD: Indicates a problem with a voltage regulator for the primary system board
- I/O Book 1 VRD: Indicates a problem with a voltage regulator for the IO Module
- I/O Book 2 VRD: Indicates a problem with a voltage regulator for the IO Module
- Storage Book VRD: Indicates a problem with a voltage regulator for the Storage Book Board
- Check the IMM Web event log. This event may be a symptom of an earlier error.
- Depending on the error perform the following steps.
- Check the IBM support site for service bulletins or firmware updates that apply to this microprocessor error.
- Replace affected Compute Book.
- Replace primary system board.
- Replace IO Book board.
- Replace Storage Book board.
Give documentation feedback