Skip to main content

80010901-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

The PCH temperature sensor has risen above its upper critical threshold. A soft shutdown will be attempted.

May also be shown as 800109012d01ffff or 0x800109012d01ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0494

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Check the IMM event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.