806f0b13-0701ffff : Bus [SensorElementName] is operating in a degraded state.

Bus [SensorElementName] is operating in a degraded state.

IMM has detected that the DMI Bus is degraded.

May also be shown as 806f0b130701ffff or 0x806f0b130701ffff

Severity

Warning

Alert Category

Warning - Other

Serviceable

yes

CIM Information

Prefix:PLAT

and ID:0246

SNMP Trap ID

60

Automatically Notify Support

no

User Response

Complete the following steps until the problem is solved:

  1. AC cycle the machine
  2. Remove microprocessor 1 and inspect the microprocessor socket for bent pins.
  3. Swap microprocessor 1 and microprocessor 2. If the error goes away, replace the original microprocessor 1.
  4. If the problem persists, System board may need to be replaced.(Trained service personnel only)