806f0107-0302ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].

An Over-Temperature Condition has been detected on [ProcessorElementName].

The microprocessor 2 temperature has risen above the critical level, causing a hard shutdown of the node.

May also be shown as 806f01070302ffff or 0x806f01070302ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0036

SNMP Trap ID

0

Automatically Notify Support

No

User Response

Complete the following steps:

  1. Check the IMM event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. Make sure that the microprocessor 2 heat sink is securely installed.
  5. (Trained service technician only) Make sure that the microprocessor 2 heat sink is installed correctly and the thermal material is correctly applied.
  6. (Trained service technician only) Replace microprocessor 2.