Skip to main content

806f020d-2b840816 : Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].

Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].

The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 22 in Compute Book 4.

May also be shown as 806f020d2b840816 or 0x806f020d2b840816

Severity

Warning

Alert Category

System - Predicted Failure

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0168

SNMP Trap ID

27

Automatically Notify Support

Yes

User Response

At the next maintenance opportunity:

  1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
  2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)
  3. Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.
  4. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlash DIMM is under warranty before replacement.