806f090c-2b810009 : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
IMM determined DIMM 9 in Compute Book 1 has been throttled due to high temperature.
May also be shown as 806f090c2b810009 or 0x806f090c2b810009
Severity
Warning
Alert Category
System - Other
Serviceable
yes
SNMP Trap ID
22
Automatically Notify Support
no
User Response
Complete the following steps until problem is solved:
- Check the IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.
- If eXFlash DIMM, make sure the eXFlash DIMM FW is updated to the latest level.
- If the DIMM problem persists and there are no other DIMMs with the same indication, replace the DIMM.
- If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication, confirm that the eXFlash DIMM is under warranty before replacement.
Give documentation feedback