Remove a rear 2.5-inch drive backplane
Follow instructions in this section to remove a rear 2.5-inch drive backplane. The procedure must be executed by a trained technician.
About this task
Attention
- Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.
- Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.
- If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover, or remove the chassis from the rack. See Remove the server from rack.
- Two people and one lifting device on site that can support up to 400 lb (181 kg) are required to perform this procedure. If you do not already have a lifting device available, Lenovo offers the Genie Lift GL-8 material lift that can be purchased at Data Center Solution Configurator. Make sure to include the Foot-release brake and the Load Platform when ordering the Genie Lift GL-8 material lift.
- The server supports one rear 2.5-inch drive backplane with the following corresponding drive backplane numbering.Figure 1. Rear 2.5-inch drive backplane numbering
Procedure
- Make preparation for this task.
- Remove the front top cover. See Remove the front top cover.
- Remove the rear top cover. See Remove the rear top cover.
- Remove all the 2.5-inch hot-swap drives and the drive bay fillers (if any) from the drive bay. See Remove a 2.5-inch hot-swap drive.
- Remove the processor air baffle. See Remove the processor air baffle.
- Record the cable connections first; then, disconnect the power and signal cables from the rear backplane. See 2.5-inch drive backplane cable routing for more information on the internal cable routing.
- Remove the 2.5-inch drive backplane.
After you finish
- Install a replacement unit. See Install a rear 2.5-inch drive backplane.
- If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
Give documentation feedback