Thermal rules
This topic provides thermal rules for the server.
Ambient temperature at sea level ≤ 25°C
CPU power ≤300W
AOC ≤ 25 GB
The performance fan and performance heat sink are installed.
The front backplane, rear backplane, rear GPU are not installed.
Max.Temp.: Maximum ambient temperature at sea level
TDP: Thermal design power
P: Performance
S: Standard
A: The Lenovo Neptune Liquid to Air Module
D: Lenovo Neptune(TM) Processor Direct Water Cooling Module
Y1: Yes
Y2: Yes when the maximum ambient temperature is less than 30 °C
Y3: Yes when the maximum ambient temperature is less than 25 °C
Y4: Yes when using the performance fan
Y5: Yes except for ThinkSystem 128GB TruDDR5 4800MHz (4Rx4) 3DS RDIMM-A v1 and ThinkSystem 256GB TruDDR5 4800MHz (8Rx4) 3DS RDIMM-A v1
Y6: Yes except for ThinkSystem 256GB TruDDR5 4800MHz (8Rx4) 3DS RDIMM-A v1
Y7: Yes when the maximum ambient temperature is less than 30 °C and the performance fan is installed.
Y8: Yes when the maximum ambient temperature is less than 35 °C and the performance fan is installed.
NA: Not applicable
Server models with front drive bays only
This section provides thermal information for server models with front drive bays only.
Front bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Processor Qty | Support DIMMs ≥ 96 GB |
---|---|---|---|---|---|---|
4 x 3.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
35°C | 200< TDP ≤ 400 | D | S or P | 2 | Y7 | |
35°C | 200< TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
4 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
25°C | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 | |
30°C Note 3 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y3 | |
30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | |
35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | |
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
8 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
30°C Note 3 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 | |
30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | |
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y2 | |
45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
10 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
10 x 2.5" NVMe (Gen 4) | 30°C Note 3 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 |
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | |
10 x 2.5" (Gen 4) | 35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y2 |
10 x 2.5" AnyBay (Gen 5) | 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
16 EDSFF | 30°C Note 2 | 200 ≤ TDP ≤ 400 | D | S | 2 | Y6 |
35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | |
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
Note
|
Server models with rear drive bays
This section provides thermal information for server models with middle or rear drive bays.
Front bays | Rear bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Processor Qty | Support DIMMs ≥ 96 GB |
---|---|---|---|---|---|---|---|
4 x 3.5" | 2 x 7mm NVMe | 25°CNote 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | ||
2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 240 | P | S | 1 or 2 | Y1 | |
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | ||
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y5 | |
4 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
25°CNote 2 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 | ||
30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | ||
2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 300 | P | S | 1 or 2 | Y5 | |
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | ||
2 x 2.5" NVMe/ U.2/U.3 | 25°CNote 2 | 320≤ TDP ≤ 400 | A | P | 2 | Y5 | |
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y5 | |
8 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
25°CNote 2 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 | ||
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 240 | P | S | 1 or 2 | Y2 | |
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y5 | |
10 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y5 | |
10 x 2.5" (Gen 4) | 2 x 7mm NVMe | 25°CNote 2 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 |
30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
10 x 2.5" NVMe (Gen 4) | 2 x 7mm NVMe 2 x 7mm SATA | 35°C | 200≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
10 x 2.5" AnyBay (Gen 5) | 2 x 7mm NVMe 2 x 7mm SATA | 35°C | 200≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
16 EDSFF | 2 x 7mm NVMe | 30°C | 200 ≤ TDP ≤ 400 | D | S | 2 | Y2 |
35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | ||
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 400 | D | S | 2 | Y7 | |
35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | ||
30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
Note
|
Server models with GPUs
This section provides thermal information for server models with GPUs.
NVIDIA® A2
NVIDIA® L4
Front bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Max. GPU Qty. | Processor Qty. | Support DIMMs ≥ 96 GB | |
---|---|---|---|---|---|---|---|---|
Front | Rear | |||||||
4 x 3.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y5 |
35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 | |
35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y5 | |
4 x 2.5" | 25°CNote 1 | 320 ≤ TDP ≤ 400 | A | P | NA | 2 | 2 | Y1 |
30°C | 240 < TDP ≤ 300 | P | P | 1 | 3 | 1 or 2 | Y5 | |
35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 | |
35°C | 200 ≤ TDP ≤ 240 | P | P | 1 | 3 | 1 or 2 | Y5 | |
8 x 2.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y5 |
35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 | |
35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y5 | |
10 x 2.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y5 |
35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y5 | |
10 x 2.5" NVMe (Gen 4) | 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
10 x 2.5" AnyBay (Gen 5) | 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
16 EDSFF | 30°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 2 | 1 or 2 | Y5 | |
Note
|