Thermal rules
This topic provides thermal rules for the server.
For the frequency of supported DIMMs, refer to Memory.
- When ThinkSystem 256GB TruDDR5 4800MHz (8Rx4) 3DS RDIMM-A v1 is installed, the following requirements should be met:
Ambient temperature at sea level ≤ 25°C
CPU power ≤300W
AOC ≤ 25 GB
The performance fan and performance heat sink are installed.
The front backplane, rear backplane, rear GPU are not installed.
When ThinkSystem Cornelis CN5000 QSFP112 1port OPA Adapter is installed, the following requirements should be met:
- For the server using the performance heat sink or the Lenovo Neptune Liquid to Air Module:
If the processor (TDP ≤ 300 watts) is installed, the ambient temperature must be limited to 35°C or lower, and the performance fan must be installed.
If the processor (TDP ≤ 400 watts) is installed, the ambient temperature must be limited to 30°C or lower, and the performance fan must be installed.
For the server using Lenovo Neptune(TM) Processor Direct Water Cooling Module:
The ambient temperature must be limited to 30°C or lower, and the standard fan must be installed.
The ambient temperature must be limited to 35°C or lower, and the performance fan must be installed.
Max.Temp.: Maximum ambient temperature at sea level
TDP: Thermal design power
P: Performance
S: Standard
A: The Lenovo Neptune Liquid to Air Module
D: Lenovo Neptune(TM) Processor Direct Water Cooling Module
Y1: Yes
Y2: Yes when the maximum ambient temperature is less than 30 °C
Y3: Yes when the maximum ambient temperature is less than 25 °C
Y4: Yes when using the performance fan
Y5: Yes except for ThinkSystem 128GB TruDDR5 4800MHz (4Rx4) 3DS RDIMM-A v1 and ThinkSystem 256GB TruDDR5 4800MHz (8Rx4) 3DS RDIMM-A v1
Y6: Yes except for ThinkSystem 256GB TruDDR5 4800MHz (8Rx4) 3DS RDIMM-A v1
Y7: Yes when the maximum ambient temperature is less than 30 °C and the performance fan is installed.
Y8: Yes when the maximum ambient temperature is less than 35 °C and the performance fan is installed.
NA: Not applicable
Server models with front drive bays only
This section provides thermal information for server models with front drive bays only.
| Front bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Processor Qty | Support DIMMs ≥ 96 GB |
|---|---|---|---|---|---|---|
| 4 x 3.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
| 35°C | 200< TDP ≤ 400 | D | S or P | 2 | Y7 | |
| 35°C | 200< TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
| 45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
| 4 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 25°C | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 | |
| 30°C Note 1, 2 and 4 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y3 | |
| 30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | |
| 35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | |
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
| 45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
| 8 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 30°C Note 1, 2 and 4 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 | |
| 30°C | 200 ≤ TDP ≤ 240 | P | S or P | 1 or 2 | Y4 | |
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | |
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
| 35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y2 | |
| 45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
| 10 x 2.5" | 25°C Note 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y2 | |
| 45°C | 200 ≤ TDP ≤ 240 | P | P | 1 or 2 | Y2 | |
| 10 x 2.5" NVMe (Gen 4) | 30°C Note 1, 2 and 4 | 320 ≤ TDP ≤ 400 | A | P | 2 | Y1 |
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | |
| 10 x 2.5" (Gen 4) | 35°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y2 |
| 10 x 2.5" AnyBay (Gen 5) | 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
| 16 EDSFF | 30°C Note 3 | 200 ≤ TDP ≤ 400 | D | S | 2 | Y6 |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | |
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
Note
| ||||||
Server models with rear drive bays
This section provides thermal information for server models with middle or rear drive bays.
| Front bays | Rear bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Processor Qty | Support DIMMs ≥ 96 GB |
|---|---|---|---|---|---|---|---|
| 4 x 3.5" | 2 x 7mm NVMe | 25°CNote 1 | 320 ≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | ||
| 2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 240 | P | S | 1 or 2 | Y1 | |
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y7 | ||
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
| 4 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 25°CNote 3 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 | ||
| 30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 300 | P | S | 1 or 2 | Y5 | |
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
| 35°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
2 x 2.5" NVMe/ U.2/U.3 | 25°CNote 1, 2, and 3 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 | |
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
| 8 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 25°CNote 1, 2, and 3 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 | ||
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
| 2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 240 | P | S | 1 or 2 | Y2 | |
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 35°C | 200 ≤ TDP ≤ 400 | D | S or P | 2 | Y8 | ||
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
| 10 x 2.5" | 2 x 7mm NVMe | 25°CNote 1 | 320≤ TDP ≤ 400 | P | P | 1 or 2 | Y1 |
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
2 x 2.5" SAS/ SATA/NVMe/ U.2/U.3 | 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | |
| 10 x 2.5" (Gen 4) | 2 x 7mm NVMe | 25°CNote 1, 2, and 3 | 320≤ TDP ≤ 400 | A | P | 2 | Y1 |
| 30°C | 200 ≤ TDP ≤ 300 | A | P | 2 | Y3 | ||
| 10 x 2.5" NVMe (Gen 4) | 2 x 7mm NVMe 2 x 7mm SATA | 35°C | 200≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
| 10 x 2.5" AnyBay (Gen 5) | 2 x 7mm NVMe 2 x 7mm SATA | 35°C | 200≤ TDP ≤ 400 | D | S or P | 2 | Y7 |
| 16 EDSFF | 2 x 7mm NVMe | 30°C | 200 ≤ TDP ≤ 400 | D | S | 2 | Y1 |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | ||
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
| 2 x 7mm SATA | 30°C | 200 ≤ TDP ≤ 400 | D | S | 2 | Y1 | |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | 2 | Y6 | ||
| 30°C | 200 ≤ TDP ≤ 300 | P | P | 1 or 2 | Y1 | ||
Note
| |||||||
Server models with GPUs
This section provides thermal information for server models with GPUs.
NVIDIA® A2
NVIDIA® L4
| Front bays | Max. Temp. | Processor TDP (watts) | Heat sink | Fan type | Max. GPU Qty. | Processor Qty. | Support DIMMs ≥ 96 GB | |
|---|---|---|---|---|---|---|---|---|
| Front | Rear | |||||||
| 4 x 3.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y1 |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 | |
| 35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y1 | |
| 4 x 2.5" | 25°CNote 1 | 320 ≤ TDP ≤ 400 | A | P | NA | 2 | 2 | Y1 |
| 30°C | 240 < TDP ≤ 300 | P | P | 1 | 3 | 1 or 2 | Y1 | |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y1 | |
| 35°C | 200 ≤ TDP ≤ 240 | P | P | 1 | 3 | 1 or 2 | Y5 | |
| 8 x 2.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y5 |
| 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 | |
| 35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y1 | |
| 10 x 2.5" | 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 3 | 1 or 2 | Y1 |
| 35°C | 200 ≤ TDP ≤ 240 | P | P | NA | 2 | 1 or 2 | Y1 | |
| 10 x 2.5" NVMe (Gen 4) | 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
| 10 x 2.5" AnyBay (Gen 5) | 35°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
| 16 EDSFF | 30°C | 200 ≤ TDP ≤ 400 | D | P | NA | 2 | 2 | Y5 |
| 30°C | 200 ≤ TDP ≤ 300 | P | P | NA | 2 | 1 or 2 | Y1 | |