Skip to main content

Impending drive failure - unassigned or standby hot spare

An unassigned drive or standby hot spare is reporting internal errors that could cause the drive to fail.

Important
  • If the affected drive is an unassigned drive, it will not be available for volume group or disk pool configuration.

  • If the affected drive is a standby hot spare, it will not be available to take over for a failed drive.

  • Because the drive has not failed, its fault indicator light will not be turned on.

  • Make sure the replacement drive has a capacity equal to or greater than the drive you will remove.

  • You can replace the drive while the storage array is receiving I/O.

CAUTION
Electrostatic discharge can damage sensitive components

Always use proper antistatic protection when handling components. Touch the components without using a proper ground may damage the equipment.

Recovery Steps​

  1. Remove the drive identified in the Details area.

  2. Wait 30 seconds, then insert the new drive. Its fault indicator light may be lit for a short time (one minute or less).

  3. Select Recheck to ensure the problem has been resolved.