00015600 : Firmware update of standby Chassis Management Module from CMM [arg1] to CMM [arg2] was not completed ([arg3]).

Firmware update of standby Chassis Management Module from CMM [arg1] to CMM [arg2] was not completed ([arg3]).

The firmware in the standby Chassis Management Module (CMM) is automatically updated if it is different from the firmware level in the primary CMM. The firmware update of the standby CMM has failed. The primary CMM and standby CMM are at different firmware levels.

Severity

Informational

Alert Category

Chassis/System Management (Informational)

Log Source

SERVPROC

Serviceable

No

Recoverable

No

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0375

SNMP Trap ID

mmTrapChassisS

Automatically Notify Support

No

User Response

Update the primary CMM to the correct firmware level. The standby CMM will be updated automatically as a background operation.