00015600 : Firmware update of standby Chassis Management Module from CMM [arg1] to CMM [arg2] was not completed ([arg3]).
Firmware update of standby Chassis Management Module from CMM [arg1] to CMM [arg2] was not completed ([arg3]).
The firmware in the standby Chassis Management Module (CMM) is automatically updated if it is different from the firmware level in the primary CMM. The firmware update of the standby CMM has failed. The primary CMM and standby CMM are at different firmware levels.
Severity
Informational
Alert Category
Chassis/System Management (Informational)
Log Source
SERVPROC
Serviceable
No
Recoverable
No
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapChassisS
Automatically Notify Support
No
User Response
Update the primary CMM to the correct firmware level. The standby CMM will be updated automatically as a background operation.
Give documentation feedback