0821C004 : Power supply [arg1] has exceeded the warning temperature.
Power supply [arg1] has exceeded the warning temperature.
The temperature of the specified power supply has exceeded the warning threshold. The system is currently operating within the allowed temperature range. However, an additional rise in temperature might result in the shutdown of devices in the chassis.
Severity
Warning
Alert Category
Power Modules (Warning)
Log Source
Power_04
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapPowerN
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module event log for any events related to the fan modules, and solve those events.
- Check the ambient room temperature to ensure that the room is not too hot.
- Check for any blockage on or near the ventilation holes on the chassis. Remove any blockages that you find.
- Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that nothing is covering the bays. Empty bays can cause a reduction in airflow to the devices in the chassis.
- Check the ambient chassis temperature. Make sure that enough fan modules are installed to sufficiently cool the devices in the chassis. See the chassis documentation to determine how many fan modules should be installed.
- Check the status of the specified power supply. If the internal fan has failed, replace the power supply.