0E20000B : Power denied to node [arg1] because it has unidentified hardware.
Power denied to node [arg1] because it has unidentified hardware.
The specified node contains components that the Chassis Management Module cannot identify. For example, the node might contain an expansion card that is not recognized. Therefore, the power requirements of the component cannot be determined.
Severity
Warning
Alert Category
Nodes (Warning)
Log Source
Node_11
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapBladeN
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module event log for other problems pertaining to the node, such as invalid vital product data (VPD), and solve them.
- If new hardware has been added to the node, check the firmware change history for applicable updates and, if necessary, update the node firmware.
- Try running the node without optional components such as expansion cards.