0001D600 : Chassis ambient temperature is out of range.
Chassis ambient temperature is out of range.
The ambient temperature of the chassis is outside of the operational range.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
Log Source
SERVPROC
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
Chassis Check Log
SNMP Trap ID
mmTrapChassisN
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the ambient room temperature to ensure that the room is not too hot.
- Check for any blockage on or near the ventilation holes on the chassis. Remove any blockages that you find.
- Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that nothing is covering the bays. Empty bays can cause a reduction in airflow to the devices in the chassis.
- Make sure that enough fan modules are installed to sufficiently cool the devices in the chassis. See the chassis documentation to determine how many fan modules are required.
Give documentation feedback