Skip to main content

06A2E001 : Chassis temperature device is unavailable.

Chassis temperature device is unavailable.

The chassis temperature is unavailable or unreadable from the rear LED card. The cooling capacity of the chassis has been set to the maximum, and the fan modules are running at full speed.

Severity

Warning

Alert Category

Chassis/System Management (Warning)

Log Source

SERVPROC

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

Chassis Check Log

CIM Information

Prefix:CMM

and ID:0158

SNMP Trap ID

mmTrapChassisN

Automatically Notify Support

No

User Response

Check the Chassis Management Module event log for communication failures for multiple components, such as I/O modules, fan modules, and power supplies. If there are communication failures for multiple components, restart the Chassis Management Module. If there are no other communication failures, replace the rear LED card.