Skip to main content

0E00B003 : I/O module [arg1] cannot power on because of insufficient power.

I/O module [arg1] cannot power on because of insufficient power.

The specified I/O module cannot power on because there is not enough power capacity in the power budget.

Severity

Warning

Alert Category

I/O Modules (Warning)

Log Source

IOMod_03

Serviceable

No

Recoverable

Yes

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0094

SNMP Trap ID

mmTrapION

Automatically Notify Support

No

User Response

Use one of the following procedures to enable the I/O module to power on:

  • Choose a different power-management policy to increase the power budget for the chassis.
  • Install additional power supplies to increase power capacity, if empty power-supply bays are available.
  • Shut down other devices in the chassis, such as nodes or I/O modules.