08556004 : An internal fan in power supply [arg1] is operating outside the recommended speed.

An internal fan in power supply [arg1] is operating outside the recommended speed.

A power supply contains two internal fans that cool the power supply. One of the fans in the specified power supply is operating outside of the normal speed range. This is a Predictive Failure Analysis (PFA) event that indicates the potential for a power-supply failure.

Severity

Warning

Alert Category

Power Modules (Warning)

Log Source

Power_04

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0041

SNMP Trap ID

mmTrapPowerN

Automatically Notify Support

Yes

User Response

At the next scheduled maintenance opportunity, replace the specified power supply.