40050001 : Chassis Management Module [arg1] is not correctly connected to the chassis.
Chassis Management Module [arg1] is not correctly connected to the chassis.
The Chassis Management Module (CMM) is not correctly installed in the chassis, or there is a problem with a connector.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
Log Source
SERVPROC
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapChassisN
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Make sure that the CMM is fully seated in the chassis.
- Remove the CMM from the chassis and check for bent pins on the connectors. If there are bent pins, submit a service request, and do not reinstall the CMM in any CMM bay in the chassis.
- Submit a service request.