Skip to main content

0EA0E001 : I/O module [arg1] POST failure, POST status: [arg2].

I/O module [arg1] POST failure, POST status: [arg2].

An error has occurred in the specified I/O module during the power-on self-test (POST). If the error is not critical, the I/O module might continue to start and function normally. If the error is critical, the I/O module will not start, and the fault LED on the I/O module will be lit.

Severity

Error

Alert Category

I/O Modules (Critical)

Log Source

IOMod_01

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

Chassis Fault

CIM Information

Prefix:CMM

and ID:0065

SNMP Trap ID

mmTrapIOC

Automatically Notify Support

No

User Response

Complete the following steps until the problem is solved:

  1. See the documentation for the specified I/O module for information about the meaning of the POST status and recovery actions that you should take.
  2. Temporarily disable all communication between the nodes and the specified I/O module in the chassis to reduce interruptions to the services that the nodes provide.
  3. Perform a service-level reset of the I/O module, which restarts the I/O module.
  4. If the firmware in the I/O module was recently updated and the POST error is not critical, revert to the previous level of firmware.
  5. Replace the I/O module.