0E00B001 : I/O module [arg1] cannot power on because of insufficient power.
I/O module [arg1] cannot power on because of insufficient power.
The specified I/O module cannot power on because there is not enough power capacity in the power budget.
Severity
Warning
Alert Category
I/O Modules (Warning)
Log Source
IOMod_01
Serviceable
No
Recoverable
Yes
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapION
Automatically Notify Support
No
User Response
Use one of the following procedures to enable the I/O module to power on:
- Choose a different power-management policy to increase the power budget for the chassis.
- Install additional power supplies to increase power capacity, if empty power-supply bays are available.
- Shut down other devices in the chassis, such as nodes or I/O modules.