0EA0E004 : I/O module [arg1] POST failure, POST status: [arg2].
I/O module [arg1] POST failure, POST status: [arg2].
An error has occurred in the specified I/O module during the power-on self-test (POST). If the error is not critical, the I/O module might continue to start and function normally. If the error is critical, the I/O module will not start, and the fault LED on the I/O module will be lit.
Severity
Error
Alert Category
I/O Modules (Critical)
Log Source
IOMod_04
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
Chassis Fault
SNMP Trap ID
mmTrapIOC
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- See the documentation for the specified I/O module for information about the meaning of the POST status and recovery actions that you should take.
- Temporarily disable all communication between the nodes and the specified I/O module in the chassis to reduce interruptions to the services that the nodes provide.
- Perform a service-level reset of the I/O module, which restarts the I/O module.
- If the firmware in the I/O module was recently updated and the POST error is not critical, revert to the previous level of firmware.
- Replace the I/O module.
Give documentation feedback