Skip to main content

40050002 : Chassis Management Module [arg1] is not correctly connected to the chassis.

Chassis Management Module [arg1] is not correctly connected to the chassis.

The Chassis Management Module (CMM) is not correctly installed in the chassis, or there is a problem with a connector.

Severity

Warning

Alert Category

Chassis/System Management (Warning)

Log Source

SERVPROC

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0197

SNMP Trap ID

mmTrapChassisN

Automatically Notify Support

No

User Response

Complete the following steps until the problem is solved:

  1. Make sure that the CMM is fully seated in the chassis.
  2. Remove the CMM from the chassis and check for bent pins on the connectors. If there are bent pins, submit a service request, and do not reinstall the CMM in any CMM bay in the chassis.
  3. Submit a service request.