00038F01 : Internal proprietary management protocol between I/O module [arg1] and CMM is offline.
Internal proprietary management protocol between I/O module [arg1] and CMM is offline.
The Chassis Management Module (CMM) cannot communicate with the specified I/O module. The I/O module might be operating normally, but the CMM cannot detect whether there are problems with the specified device. This is an internal Ethernet issue for advanced communication. The I2C interface is independent.
Severity
Warning
Alert Category
I/O Modules (Warning)
Log Source
IOMod_01
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
Chassis Check Log
SNMP Trap ID
mmTrapION
Automatically Notify Support
Yes
User Response
Temporarily disable all communication between the nodes and the specified I/O module in the chassis to reduce interruptions to the services that the nodes provide. Perform a service-level reset of the I/O module, which restarts the I/O module. If the service-level reset does not correct the problem, replace the I/O module.
Give documentation feedback