Replacing the N2215 SAS/SATA Host Bus Adapter for System x

User this information for instructions on how to replace the N2215 SAS/SATA Host Bus Adapter.

Note
For additional information and notes about installing adapters, see Installing an adapter.

You can purchase the optional N2215 SAS/SATA Host Bus Adapter for System x. This solid state driver controller provides no RAID support; however, it helps to provide optimized performance for applications that do not need RAID support. See Supported host bus adapters for more information about this adapter. For configuration information, see the documentation at the Lenovo Data Center Support website.

Attention
Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
To install the adapter, complete the following steps:
Note
This adapter can only be installed in the storage book.
  1. Touch the static-protective package that contains the new N2215 SAS/SATA host bus adapter to any unpainted surface on the outside of the server; then, grasp the adapter by the top edge or upper corners of the adapter and remove it from the package.
  2. Align the adapter so that the keys align correctly with the connector on the storage book board.
  3. Insert the adapter into the connector on the storage book board until it is firmly seated.
    Attention
    Make sure that the adapter is seated correctly. Incomplete insertion might cause damage to the storage book board or the adapter.
  4. Close the PCIe retention lever.
  5. Reconnect the cables to the adapter.
  6. Reinstall the storage book.
  7. Perform any configuration tasks that are required for the adapter.
  8. Reconnect the power cord and any cables that you removed.
  9. Turn on the peripheral devices and the server.