Skip to main content

FQXSFMA0049M : DIMM [arg1] disabled due to memory module power failure. DIMM [arg2] detected and good, DIMM [arg3] not detected.

DIMM [arg1] disabled due to memory module power failure. DIMM [arg2] detected and good, DIMM [arg3] not detected.

Parameters

[arg1] Disabled slot

[arg2] Disabled but detected DIMMs

[arg3] Disabled but not detected DIMMs e.g. “DIMM 1,2 disabled due to memory module power failure. DIMM 2 detected and good, DIMM 1 not detected.”

This message is reported when DDRIO power failure detected.

Severity

Warning

User Action

Complete the following steps:

  1. Power off the system and remove A/C power.
  2. Check DIMM slots specified in the message. If DIMM installed but undetected, remove it and then restore the A/C power and power on the system.
  3. If all DIMMs detected or error persists after removing undetected DIMMs, reseat all the DIMMs in the slots specified by the message and then restore the A/C power and power on the system.
  4. If the problem persists or undetected DIMM needs to be replaced, collect Service Data logs and contact Lenovo Support.