Skip to main content

FQXSFMA0008M : DIMM [arg1] has failed the POST memory test. [arg2]

DIMM [arg1] has failed the POST memory test. [arg2]

Parameters

[arg1] DIMM slot silk label

[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g., "739E68ED-VC10 FRU 0123456"

This message is reported when DIMM has been disabled by training error.

Severity

Error

User Action

Complete the following steps:

  1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the correct population sequence.
  2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot to F1 setup and enable the DIMM. Reboot the system.
  3. Swap the DIMM from failure location to another known good location to see if the failure follow the DIMM or DIMM slot.
  4. If this problem was encountered during an XCC / UEFI update process:
    1. Power cycle the system by removing power for a few seconds.
    2. Clear CMOS settings by removing battery for a few seconds.
  5. If the problem persists, collect Service Data logs and contact Lenovo Support.