Skip to main content

FQXSPIO0027M : Fault in M2 adapter(serial number: [SerialNumber]) on system [ComputerSystemName].

Fault in M2 adapter(serial number: [SerialNumber]) on system [ComputerSystemName].

This message is for the use case when an implementation has detected a fault in a slot.

Severity

Error

Alert Category

Critical - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0330

SNMP Trap ID

50

Automatically Notify Support

Yes

User Action

Complete the following steps until the problem is solved:

  1. Reseat the affected M.2 adapter.
  2. Update the server firmware (UEFI and XCC) and adapter firmware.
    Note
    Some cluster solutions require specific code levels or coordinated code updates.
  3. If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster solution before the update.
  4. If the problem persists, collect service data log.
  5. Contact Lenovo Support.