Skip to main content

FQXSPPW0132N : Fan [FanGroup] powergood has transitioned to non-recoverable.

Fan [FanGroup] powergood has transitioned to non-recoverable.

This message is for the use case when an implementation has detected a fan non-recoverable fault has occurred.

Severity​

Error

Alert Category​

Critical - Voltage

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0856

SNMP Trap ID​

1

Automatically Notify Support​

Yes

User Action​

Complete the following steps until the problem is solved:

  1. Perform virtual system reseat or A/C power cycle.
  2. If the error persists, remove A/C power and any recently installed components.
  3. If the system successfully powers on, complete the following steps:
    1. Check the ServerProven website (https://serverproven.lenovo.com/) to make sure that recently installed components are compatible with the system.
    2. Inspect the previously installed components for physical damage and fix it.
    3. If the system does not successfully power on or if this is not the first occurrence of this problem, go to step 4.
  4. If the problem persists, collect service data log.
  5. Contact Lenovo Support.