FQXSPPW0101J : Power redundancy is degraded.

Power redundancy is degraded.

This message is for the use case when power redundancy is degraded.

Severity​

Warning

Alert Category​

Warning - Redundant Power Supply

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0804

SNMP Trap ID​

10

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check if one of the power supplies is missing, failed, or not installed properly. If so, reinstall it.
  2. Check the maximum power supply rate and power capping policy. If any power supply unit does not meet the requirements, change the power supply unit or modify the power capping mechanism.
  3. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
    Note
    If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster solution before the update.
  4. If the problem persists, collect service data log.