Skip to main content

FQXSPCA0007J : Ambient temperature going high (upper non-critical) has asserted.

Ambient temperature going high (upper non-critical) has asserted.

This message is for the use case when an implementation has detected an upper non-critical sensor going high has asserted.

Severity​

Warning

Alert Category​

Warning - Temperature

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0490

SNMP Trap ID​

12

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check the XCC event log for any fan or cooling related issues and address them first.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are correctly installed in place and keep clean.
  3. Make sure that the room temperature meets operating specifications.
  4. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
  5. If the problem persists, collect service data log.
  6. Contact Lenovo Support.