Skip to main content

FQXSPPW0110M : Non-redundant:Insufficient Resources for Power Resource has asserted.

Non-redundant:Insufficient Resources for Power Resource has asserted.

This message is for the use case when a redundancy set has transitioned to Non-redundant: Insufficient Resources.

Severity

Error

Alert Category

Critical - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0810

SNMP Trap ID

9

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check if one of the power supplies is missing, failed, or not installed properly. If so, reinstall it.
  2. Check the maximum power supply rate and power capping policy. If any power supply unit does not meet the requirements, change the power supply unit or modify the power capping mechanism.
  3. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
    Note
    If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster solution before the update.
  4. If the problem persists, collect service data log.
  5. Contact Lenovo Support.